Among all kinds of mechanical and electrical equipment in all walks of life in China, the motors matched with fans account for about 60% of the installed capacity of national motors, and the power consumption accounts for about one-third of the total power generation in China. In particular, Sweeper fan Price Most fans have the phenomenon of pulling a cart from a horse during use. In addition, due to changes in production and technology, it is necessary to frequently adjust the gas flow, pressure, temperature, etc; Many units still adopt the backward way of adjusting the opening degree of the wind shield or valve to adjust the gas flow, pressure, temperature, etc. In fact, this is to meet the requirements of process and working conditions for gas flow regulation by artificially increasing resistance at the cost of wasting electric energy and money. This backward regulation mode not only wastes valuable energy, but also has poor regulation accuracy, which is difficult to meet the requirements of modern industrial production and services, and has serious negative effects. With the continuous improvement and development of frequency conversion technology in recent ten years. The performance of variable frequency speed regulation is becoming increasingly perfect, customized Sweeper fan It has been widely used in AC speed regulation in different fields. It has brought considerable economic benefits to enterprises and promoted the automation process of industrial production.
customized Sweeper fan Fans can be divided into axial flow fans, centrifugal fans and diagonal flow (mixed flow) fans according to the flow direction after the airflow enters the impeller. Fans are divided into press in local fans (hereinafter referred to as press in fans) and flame-proof motors placed outside or inside the flow channel, and flame-proof motors placed inside the explosion-proof sealing chamber of the extraction type local fans (hereinafter referred to as extraction fans) according to their purposes. Sweeper fan Price Fans can also be divided into single-stage, two-stage or multi-stage pressurization fans according to the form of pressurization. For example, 4-72 is single-stage pressurization, and high-end fan is multi-stage pressurization fan. Fans can be divided into axial flow fans, mixed flow fans, roof fans, air conditioning fans, etc. Fan can be divided into negative pressure fan, low pressure fan, medium pressure fan and high pressure fan according to pressure. According to the outlet pressure (pressure rise), it can be divided into: ventilator (≤ 15000 Pa), blower (15-350000 Pa), compressor (≥ 350000 Pa)
2. The influence of the total pressure deviation Δ H of the fan itself was not considered during selection. When the actual total pressure of the fan was positive deviation, the flow increased; When the actual total pressure of the fan is negative deviation, the flow decreases. See (a) below. The relationship between the deviation of the pipe network characteristic curve and the total pressure and the flow can be eliminated by one of the following methods when the fan starts to officially operate after new installation, or when the flow is too large or too small during use. 1. Use the opening and closing of throttling device to adjust the flow. 2. Increase or decrease the flow by increasing or decreasing the fan speed. 3. Use a new fan with higher or lower pressure to increase or decrease the flow. 4. Change the pipe network to reduce the resistance coefficient of the pipe network to increase the flow. It must be pointed out that throttling devices are generally used to regulate the flow. However, when the actual flow is much larger than the required flow, this method wastes too much power and is very uneconomical. If conditions permit, the fan speed is usually reduced or the fan with lower pressure is replaced. When the throttling device is fully open, the flow is still too small. At this time, the throttling device has lost its function, so try to reduce the resistance coefficient of the pipe network to increase the flow, or increase the fan speed and replace the fan with higher pressure. However, the speed of the fans directly connected to the motor and the coupling cannot be changed generally. Only the fan driven by the pulley can increase or decrease the speed by changing the diameter of the pulley, but the speed of the fan cannot exceed the speed max in the performance and selection table.
The selection of fans Product performance and fan performance listed in the selection table are based on the performance of delivering air under standard conditions. Therefore, when the use condition is non-standard, the H4-72-12 centrifugal fan must convert the use performance into the performance under standard conditions according to the relationship in the table above, and then select according to the performance and selection table. (3) Treatment of excessive or insufficient flow During use, excessive or insufficient flow often occurs. There are many reasons for this phenomenon. If the flow is high and low during use, it is mainly because the resistance in the pipe network is high and low, or the fan works in a non working area. If it is gradually reduced after a long time during use, it is mainly due to pipe network blockage. After the fan is newly installed, the flow is too large or insufficient during the formal operation. The main reasons for this phenomenon are as follows: 1. The actual value of pipe network resistance is too different from the calculated value. In the general pipe network characteristic equation, H=KQ2, if the actual value K of K-resistance coefficient is less than the calculated value K, the flow will increase; If the actual value K is greater than the calculated value K, the flow decreases. See (b) below.
The selection basis of wet dust collector is as follows. ① customized Sweeper fan Dust removal efficiency. Whether the efficiency of wet dust collector is high or not is one of the most important performance indicators to be selected. Under certain conditions, the gas flow, specific dust pollutants, and the gas state have a direct impact on the collection efficiency. ② Operational flexibility. Sweeper fan Price Any operating equipment shall consider its negative flow, and the impact on the capture efficiency when the air flow exceeds or is lower than the design value; Similarly, it is necessary to know how to operate when the dust concentration is unstable or continuously higher than the design value. ③ Hydrophobicity. The purification efficiency of wet dust collector for hydrophobic dust is not high, and generally it is not suitable for the operation at the design value. ④ Adhesion. Wet dust collector can purify cohesive dust, but flushing and cleaning shall be considered to prevent blockage, ⑤ corrosiveness. Anticorrosion measures shall be considered when purifying corrosive gas, ⑥ water consumption. How much water is consumed by the dust remover, sewage treatment and anti freezing measures for water in winter. ⑦ Mud treatment. Mud treatment is an inevitable problem for wet dust collectors, and efforts should be made to reduce the harm of pollution. ⑧ Operation and maintenance. Yichun Sweeper fan Price Generally, moving or rotating parts inside the dust remover shall be avoided, and it shall be noted that if the gas passes through the channel section too small, it will cause blockage.
Forecast from domestic market capacity. Yichun Sweeper fan Price Fans vary greatly according to different pressure and flow requirements. Therefore, the fan demand should be differentiated according to its type and size, and predicted according to the demand of different industries. According to incomplete statistics, the annual average growth rate of national fan output was 13.8% from 1980 to 1996. customized Sweeper fan It is estimated that the total output of wind turbines in China will be 2.6 million to 2.9 million in 2005 and 3.1 million to 3.25 million in 2010. According to the statistics of fan industry over the years, it is predicted that the output of centrifugal compressors will be 1.6 million to 1.8 million in 2005 and 2 million to 2.1 million in 2010; The output of axial compressor is 260000 in 2005, and is expected to reach 360000 in 2010; The market share of turbine compressor and blower will reach about 70% in 2005