Industrial dust collector manufactor In the use of wet electrostatic precipitator, we will encounter problems of one kind or another. If we do not know how to solve them, we will not know what to do. What are the reasons for the failure of wet electrostatic precipitator? Next, I will analyze it for you. (1) major Industrial dust collector The causes of electrical failure include: electrical components are damaged, corona electrode is not adjusted properly, and porcelain bushing and post insulator through the wall are damaged. ① The electrical components are damaged, such as the fuse is blown, the high-voltage silicon rectifier tube is broken down or the thyristor is damaged, which can lead to the power failure; If the milliammeter is damaged or the transformer fails, the phenomenon of fault type (3) will occur. ② If the nickel chromium alloy wire is not used, the corona electrode will be rusted and broken after being used for a short time. The tension of corona wire is uneven, the force is uneven, and the overload of individual corona electrode will also cause the corona electrode to break; If the corona electrode is not installed in place, deviates from the center of the settling tube, or has too much scale, the electric field will flash over frequently, or even the operation will be interrupted. ③ If the mechanical properties of the through wall porcelain bushing and post insulator are not up to standard and cannot bear the tension of the upper and lower hangers, the insulator will be damaged and cracked. The insulator box temperature control is unreasonable, and the temperature is low or changes violently, which will also cause the insulator to be damaged and cracked; Excessive scale on the surface of insulator will also cause damage and crack of insulator. The final result is that the electric field is grounded, the operation of the electrostatic precipitator is interrupted, and faults (2) and (4) occur.

Industrial dust collector manufactor Different types of dust remover equipment have their own precautions. When we usually use the dust remover equipment, we should tell my customer friends some application matters. What matters should we consider when using wet electrostatic precipitator? Matters needing attention on the application of wet electrostatic precipitator. 1. The wet electrostatic precipitator shall be put into the insulator chamber electric heating and hot air purging system at least 8 hours in advance to ensure that the temperature of the insulator chamber is more than 60 ℃. 2. The wet desulfurization system of the wet electrostatic precipitator is put into operation early to prevent dry and high-temperature smoke from entering the wet electrostatic precipitator, which will lead to scaling of internal parts and damage of internal anti-corrosion coating. three major Industrial dust collector The wet dust collector can be opened when the following three conditions are met together: 3.1 The wet electrostatic precipitator is operated with 25% of the oil gun remaining and 35% of the powder feeding is normal and stable or the oil gun is completely withdrawn. 3.2 The temperature of flue gas entering the wet electrostatic precipitator is lower than 70 ℃. 3.3 Desulfurization equipment has been opened. 4. The process of opening the wet electrostatic precipitator: first open the low-pressure water supply system and then the high-pressure power supply system.

The fan is allowed to start at full voltage or at reduced voltage, but it should be noted that the current at full voltage starting is about 5~7 times the rated current, and the reduced voltage starting torque is proportional to the square of the current. When the grid capacity is insufficient, the reduced voltage starting should be used. (When the power is greater than 11KW, it is advisable to adopt the step-down starting.) When the fan is in test run, Industrial dust collector manufactor Carefully read the product manual and check whether the wiring method is consistent with the wiring diagram; Carefully check whether the working voltage of the power supply to the fan meets the requirements, whether the power supply is out of phase or in phase, and whether the capacity of the electrical components provided meets the requirements. During commissioning, the number of people shall not be less than two. One person shall control the power supply and the other person shall observe the operation of the fan. If any abnormality is found, stop the machine immediately for inspection; First, check whether the rotation direction is correct; After the fan starts to run, immediately check whether the running current is balanced and whether the current exceeds the rated current; major Industrial dust collector If there is no normal phenomenon, stop the machine for inspection. After five minutes of operation, stop the machine to check whether the fan is abnormal, and start the machine again after confirming that there is no abnormal phenomenon. When the two speed fan is tested, start the low speed fan first and check whether the rotation direction is correct; When starting the high-speed train, the fan must be stopped before starting to prevent the switch tripping and motor damage caused by high-speed reverse rotation. When the fan reaches the normal speed, check whether the input current of the fan is normal, and the operating current of the fan cannot exceed its rated current. If the operating current exceeds its rated current, check whether the voltage supplied to the fan is normal. The motor power required by the fan refers to the higher power required for centrifugal fan and fan box when the air inlet is fully open under certain working conditions. If the air inlet is fully opened for operation, the motor may be damaged. During fan commissioning, it is better to close the valve on the inlet or outlet pipeline of the fan, open the valve gradually after operation until the required working condition is reached, and pay attention to whether the operating current of the fan exceeds the rated current

Foshan major Industrial dust collector Forecasts from foreign markets. The member units of China General Machinery Fan Industry Association exported 7969 fans in 2000, with the export delivery value of 81.157 million yuan. From 1991 to 2000, the total number of exported fans was 72876, and the total value of export delivery was 747.26 million yuan. Industrial dust collector manufactor The trend of global economic integration is becoming more and more obvious. The economies of all countries will further depend on each other. International economic cooperation and exchanges will become closer and closer. The international market is at a stage of significant intersection and integration. At the same time, the pace of global industrial restructuring is accelerating, and significant progress has been made in the scale and depth of international division of labor. Developed countries continue to shift industrial production to capital intensive and technology intensive industries, and labor-intensive products are transferred to developing countries and regions. This provides a good development opportunity for China to play its own advantages and enter the international market. Since the 1970s, China has introduced foreign advanced technology of centrifugal compressor, which has improved the product grade through digestion, absorption and innovation. As long as the quality and delivery time are guaranteed and the price advantage is used, it is competitive internationally. Especially after China's entry into WTO, it is entirely possible to increase the fan export. From the historical analysis, the main export varieties are small and medium-sized fans and fan accessories. The main gap between domestic enterprises producing such fans is that the surface quality cannot meet the export requirements. If the appearance quality is improved and the price is favorable, the prospect in the foreign market is broad. From 1991 to 2000, the fan exports of small and medium-sized fans were not stable enough, and there was no obvious growth trend. However, with the continuous progress of technology, it is expected that the export volume of such fans will continue to increase, and it is predicted that the annual average growth rate will be about 5% on the basis of 2000. major Industrial dust collector The export of centrifugal compressors and blowers increased significantly from 1991 to 2000, reaching 870000 sets in 2000. The main exporting countries are India, Pakistan, Iran, Vietnam and other developing countries. It is expected that this trend will continue to develop, reaching 1 million units per year.