The wet electrostatic precipitator has been recognized by users due to many advantages in the process of application. It can remove dust and purify waste gas. It is an environmental protection equipment that can be used in a wide range of situations. What steps can we take when using this environmental protection equipment? today Axial flow fan company Let's take a detailed look. 1. First, close the power switch of the wet electrostatic precipitator. When the power indicator is on, the local remote switch will be switched to the local position; 2. Press the fan start button, and then observe whether the fan of the wet electrostatic precipitator rotates correctly. After the fan rotates normally, normal dedusting operation can be started; 3、 large Axial flow fan After a period of time, if you need to clear and discharge the ash, you can press the ash cleaning button on the wet electrostatic precipitator; 4. Turn over the pulse valve to clear the ash, and the screw machine and ash discharge valve will also work together. The above is the whole content of the application process of the wet electrostatic precipitator. What we need to remind us here is that the equipment can be started only after the position is adjusted before it is used. During the dust removal process of the equipment, the humidification function can be started to keep the ground wet, so that the wet electrostatic precipitator can have a better application effect.
River pool Axial flow fan company What is the operation content of wet electrostatic precipitator. The dust vapor of the wet electrostatic precipitator enters the middle and lower shells through the air inlet, and the dust vapor enters the upper shell according to the precipitator. In the whole process, dust and gas are separated due to various practical functions of the dust bag. The dust removal bag expands greatly under the instantaneous reverse direction effect of the cyclone, so that the dust accumulated on the surface of the dust removal bag decreases, and the filter bag of the dust remover is modified. According to the whole cleaning process and time addition of the dedusting bag, try to stack a large amount of smoke and dust on the filter bag of the electrostatic induction precipitator. According to the size of the dedusting bag, the amount of steam gradually decreases, and the friction resistance of the dedusting bag increases. The smoke and dust are absorbed by the dust removal bag, and the vapor enters the upper shell through the filter screen pipe and is discharged from the vent. large Axial flow fan In order to control the friction resistance within the limit range, a dedusting pulse controller is required to output steam. Open the pressure regulating valve in sequence, open the pulse solenoid valve of the wet electrostatic precipitator, and the pulse solenoid valve will instantly compress the air in the airbag. Dust falls into the silo and is discharged from the shell through the discharge valve.
3. When installing Type C and Type B, ensure that the two pulley positions are on the same plane, and the flatness tolerance is 0.5mm. 4. When installing Type D, use a dial indicator and feeler gauge to measure the coaxiality of the fan spindle and motor spindle and the parallelism of both ends of the coupling. The coaxiality tolerance of two shafts is 0.2mm, the parallelism tolerance of both ends of the coupling is 0.2mm, and the spacing between two planes of the coupling is 5 to 8mm. 5. After the fan is installed, move the rotor with hand or lever to check whether it is too tight or collided. The test run can be carried out without overtightening or collision. 6. After the motor is installed, the belt pulley or coupling guard shall be installed. If the air inlet is not connected to the air inlet pipe, the guard net or other safety devices (provided by the user) shall also be provided. 7. Other parts shall be installed according to the corresponding positions in the drawing. 8. Add N46 (ISO VG46, 30) in summer and N32 (ISO VG32, 20) in winter. The oil level should be at 1/2 of the oil window.
River pool large Axial flow fan Forecasts from foreign markets. The member units of China General Machinery Fan Industry Association exported 7969 fans in 2000, with the export delivery value of 81.157 million yuan. From 1991 to 2000, the total number of exported fans was 72876, and the total value of export delivery was 747.26 million yuan. Axial flow fan company The trend of global economic integration is becoming more and more obvious. The economies of all countries will further depend on each other. International economic cooperation and exchanges will become closer and closer. The international market is at a stage of significant intersection and integration. At the same time, the pace of global industrial restructuring is accelerating, and significant progress has been made in the scale and depth of international division of labor. Developed countries continue to shift industrial production to capital intensive and technology intensive industries, and labor-intensive products are transferred to developing countries and regions. This provides a good development opportunity for China to play its own advantages and enter the international market. Since the 1970s, China has introduced foreign advanced technology of centrifugal compressor, which has improved the product grade through digestion, absorption and innovation. As long as the quality and delivery time are guaranteed and the price advantage is used, it is competitive internationally. Especially after China's entry into WTO, it is entirely possible to increase the fan export. From the historical analysis, the main export varieties are small and medium-sized fans and fan accessories. The main gap between domestic enterprises producing such fans is that the surface quality cannot meet the export requirements. If the appearance quality is improved and the price is favorable, the prospect in the foreign market is broad. From 1991 to 2000, the fan exports of small and medium-sized fans were not stable enough, and there was no obvious growth trend. However, with the continuous progress of technology, it is expected that the export volume of such fans will continue to increase, and it is predicted that the annual average growth rate will be about 5% on the basis of 2000. large Axial flow fan The export of centrifugal compressors and blowers increased significantly from 1991 to 2000, reaching 870000 sets in 2000. The main exporting countries are India, Pakistan, Iran, Vietnam and other developing countries. It is expected that this trend will continue to develop, reaching 1 million units per year.
The fan is allowed to start at full voltage or at reduced voltage, but it should be noted that the current at full voltage starting is about 5~7 times the rated current, and the reduced voltage starting torque is proportional to the square of the current. When the grid capacity is insufficient, the reduced voltage starting should be used. (When the power is greater than 11KW, it is advisable to adopt the step-down starting.) When the fan is in test run, Axial flow fan company Carefully read the product manual and check whether the wiring method is consistent with the wiring diagram; Carefully check whether the working voltage of the power supply to the fan meets the requirements, whether the power supply is out of phase or in phase, and whether the capacity of the electrical components provided meets the requirements. During commissioning, the number of people shall not be less than two. One person shall control the power supply and the other person shall observe the operation of the fan. If any abnormality is found, stop the machine immediately for inspection; First, check whether the rotation direction is correct; After the fan starts to run, immediately check whether the running current is balanced and whether the current exceeds the rated current; large Axial flow fan If there is no normal phenomenon, stop the machine for inspection. After five minutes of operation, stop the machine to check whether the fan is abnormal, and start the machine again after confirming that there is no abnormal phenomenon. When the two speed fan is tested, start the low speed fan first and check whether the rotation direction is correct; When starting the high-speed train, the fan must be stopped before starting to prevent the switch tripping and motor damage caused by high-speed reverse rotation. When the fan reaches the normal speed, check whether the input current of the fan is normal, and the operating current of the fan cannot exceed its rated current. If the operating current exceeds its rated current, check whether the voltage supplied to the fan is normal. The motor power required by the fan refers to the higher power required for centrifugal fan and fan box when the air inlet is fully open under certain working conditions. If the air inlet is fully opened for operation, the motor may be damaged. During fan commissioning, it is better to close the valve on the inlet or outlet pipeline of the fan, open the valve gradually after operation until the required working condition is reached, and pay attention to whether the operating current of the fan exceeds the rated current