Y5-48 boiler centrifugal induced draft fan is designed for industrial boilers (1~20T/h) that burn various coals and are equipped with smoke suppression devices. The maximum temperature shall not exceed 250 ℃ for those with equivalent air inlet conditions and suitable performance. A dedusting device with an efficiency of not less than 85% must be installed before the induced draft fan to reduce the dust content of flue gas entering the fan, so as to improve the service life of the fan.
The induced draft mechanism is single suction. The machine numbers include № 4, 5, 6.3, 8, 10 and 12.5. The fan can be made into right rotation or left rotation.
The outlet position of the fan is expressed by the air outlet angle of the fan housing. The "left" and "right" can be made into six angles of 0 °, 45 °, 90 °, 135 °, 180 ° and 225 °.
The fan is composed of impeller, casing, air inlet, regulating valve, transmission group, etc.
Impeller: there are 12 backward inclined flat blades, made of 16Mn, welded between the arc cone wheel cover and the flat wheel disc. After static and dynamic balance correction, it operates stably and has high strength.
Casing: it is welded into a volute shaped integral structure with steel plates and fixed at the inlet side of the casing with bolts.
Air inlet: It shall be made into a convergent and streamlined overall structure and fixed at the inlet side of the casing with bolts.
Regulating valve: the blade of regulating valve is flower shaped, and above № 8, "left" and "right" turn to universal. The volute plate is also provided with an ash removal door, which is convenient for removing the ash accumulated on the blade and in the casing to ensure the balance and pneumatic performance of the impeller
Drive group: composed of main shaft, bearing box, pulley, etc. The main shaft is made of high-quality steel, with rolling bearings and water-cooled integral bearing box. Therefore, it is important to install water pipes. The water consumption varies with the ambient temperature, generally 0.5~1m3. The bearing box is equipped with a thermometer and an oil level indicator. The lubricating oil is No. 30 engine oil, and the lubricating oil is No. 30 engine oil. The amount of oil added shall comply with the requirements of the oil level mark.
Performance Parameters of Y5-48 Boiler Ventilation and Induced Draft Fan
speed r/min | S/N | flow m3/h | Total pressure Pa | Motor | Spindle pulley |
model | Power KW | Code | Specifications |
three thousand and five hundred | one two three four five six seven | two thousand nine hundred and thirty-two three thousand three hundred and seventy-four three thousand eight hundred and seven four thousand two hundred and fifty-four four thousand six hundred and eighty-six five thousand one hundred and forty-three five thousand five hundred and sixty-four | two thousand two hundred and twenty-one two thousand two hundred and fifty-four two thousand one hundred and seventy-three two thousand and sixty-eight one thousand nine hundred and fourteen one thousand seven hundred and twenty-six one thousand five hundred and one | Y132S1-2 | five point five | A | one thousand and eight hundred |
three thousand one hundred and fifty | one two three four five six seven | two thousand six hundred and two two thousand nine hundred and ninety-three three thousand three hundred and seventy-eight three thousand three hundred and seventy-five four thousand one hundred and fifty-eight four thousand five hundred and sixty-three four thousand nine hundred and thirty-seven | one thousand seven hundred and forty-six one thousand seven hundred and seventy-two one thousand seven hundred and eight one thousand six hundred and twenty-six one thousand five hundred and five one thousand three hundred and fifty-seven one thousand one hundred and eighty | Y112M-2 | four | A | one thousand and eight hundred |
two thousand and eight hundred | one two three four five six seven | two thousand three hundred and thirteen two thousand six hundred and sixty-one three thousand and three three thousand three hundred and fifty-five three thousand six hundred and ninety-six four thousand and fifty-six four thousand three hundred and eighty-eight | one thousand three hundred and seventy-seven one thousand three hundred and ninety-eight one thousand three hundred and forty-eight one thousand two hundred and eighty-three one thousand one hundred and eighty-eight one thousand and seventy-one nine hundred and thirty-two | Y100L-2 | three | A | one thousand and six hundred |
two thousand and five hundred | one two three four five six seven | two thousand and sixty-five two thousand three hundred and seventy-six two thousand six hundred and eighty-one two thousand nine hundred and ninety-six three thousand and three hundred three thousand six hundred and twenty-two three thousand nine hundred and eighteen | one thousand and ninety-seven one thousand one hundred and thirteen one thousand and seventy-three one thousand and twenty-two nine hundred and forty-six eight hundred and fifty-three seven hundred and forty-two | Y90L-2 | two point two | A | one thousand and six hundred |